Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T13CM05422
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2013 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/14/2013 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 11/14/2013 | PLUMBING - INTERMEDIATE | Partial Approval | STRAPING DENIED ADD SUPPORTS TO EMER SHWR DRAIN. SECURE PIPES W/ CODE APPROVED CLAMPS OR PROVIDE A LISTING & INSTALL INSTRUCTIONS FOR PLASTIC STRAP. |
|
| 11/13/2013 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/13/2013 | PLUMBING - INTERMEDIATE | Denied | KIT VENT OFFSET, TEST THROUGH ROOF AFTER CORRECTION. P TAPE - PROVIDE LISTING & INSTALL INSTRUCTIONS 2609. HORIZONTAL SUPPORTS, MID STORY SUPPORTS | |
| 11/08/2013 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/08/2013 | PLUMBING - INTERMEDIATE | Denied | SLOPE SUPPORTS. INSTALL PIPING SUPPORT AS REQUIRED IN IRC SEC 2609. SUPPORT ABS AT EACH CONNECTION. PROVIDE A STEP LADDER TO INSPECT PIPING SLOPE. SECURE ALL CLOSET FLANGES PER 3003.19. KIT VENT MAY NOT OFFSET HORIZONTALLY BELOW FLOOD LEVEL. TEST SHOWER PAN. TEST DWV THRU ROOF. | |
| 11/05/2013 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 11/05/2013 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 303.2 P-2609 IRC. INSTALLATION OF MATERIALS. SUPPORTS & CLOSET FLANGES. P2705.1 #1 CLOSET FLANGES ALSO P3003.19 |