Permit: T13CM05347

Parcel: 13810017D

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
11/13/2013 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
11/04/2013 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/04/2013 ELECTRIC - RECONNECT Denied NOTE 1, 2, 3, 4 - NOTES FROM PREVIOUS
09/04/2013 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/04/2013 ELECTRIC - RECONNECT Denied 1. SECURE ALL EXTERIOR BOXES & CONDUIT TO CORE. SEAL OPENINGS IN BOXES. PROVIDE EXT FITTINGS ALL EXTERIOR CONDUITS.
2. EXTERIOR LIGHT FIXTURE EAST PORCH NOT TO CODE
3. SECURE MAIN PANEL TO WALL PER CODE. SECURE RISER 2 RISER CLAMPS. 30 AMP SQUARE D BREAKER TO MATCH PANEL TYPE. SECURE 4 BARE TO BUILDING
4. WEATHER CAP EXT BOXES
5. SMOKE ALARM BEDROOMS & OPPOSITE SIDE OF DOORS PER SPECS
6. BEDROOMS LACK PROPER EGRESS