Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2013 | ELECTRIC - FINAL | Approved | BOTH UNITS APPROVED FOR RECONNECT | |
| 09/13/2013 | ELECTRIC - FINAL | Partial Approval | 3926 WAS THE ONLY UNIT LOOKED AT AND CLEAR TO RECN | |
| 09/11/2013 | ELECTRIC - FINAL | Denied | 1. APPEARS TO BE A SERVICE UPGRADE. IF SO, PLEASE HAVE THAT ADDED TO PERMIT 2. LOCKBOX HAS NO KEY INSIDE FOR ACCESS TO UNIT |
|
| 08/12/2013 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 08/12/2013 | ELECTRIC - FINAL | Denied | DOUBLE & TRIPLE LUGGING OF WIRES ON THE LOAD SIDE OF SERVICE DISCONNECTS IS NOT ALLOWED. THE CIRCUITS FOR DRYERS & ROOFTOP EQUIPMENT WILL HAVE TO COME FROM THE SUBPANELS OR PROVIDE NEW PANELS AT THE SERVICE. ALL OUTDOOR RECEPTACLES MUST BE GFI. WIRE SPLICE NOT TO CODE IN LAUNDRY ROOM IN 3928. SECURE WIRE TO LIGHT & SECURE WASHER RECEPTACLE. |