Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T13CM04841
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/20/2013 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
09/19/2013 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
09/18/2013 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
09/18/2013 | PLUMBING - ROUGH, SOIL | Denied | YOU STILL HAVE BACK PITCH ON KITCHEN BRANCH LINE. INSTALL KIT DRAIN FITTING OR IDENTIFY DRAIN & VENT RISERS SO THAT NO MISTAKE IS MADE AT TOP OUT. | |
09/17/2013 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
09/17/2013 | PLUMBING - ROUGH, SOIL | Denied | 1. CORRECT BACK PITCH ON BLK WATER 2. PROVIDE A WYE PATTERN FITTING FOR FOOT 3. VENT, ALSO, INSTALL CO AND DRAIN FITTING @ ISLAND (OR 10 DRAIN & VENT RISERS) 4. MAX SLOPE ON TRAP ARM IS 1/4" PER FOOT 5. CONNECT TRACER WIRES W/ WATER RESISTANT WIRE NUT 6. REMOVE ANY ROCKS TOUCHING PIPES |
|
09/16/2013 | PLUMBING - ROUGH, SOIL | Not ready for Inspection |