Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T13CM04841

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
09/20/2013 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/19/2013 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/18/2013 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/18/2013 PLUMBING - ROUGH, SOIL Denied YOU STILL HAVE BACK PITCH ON KITCHEN BRANCH LINE. INSTALL KIT DRAIN FITTING OR IDENTIFY DRAIN & VENT RISERS SO THAT NO MISTAKE IS MADE AT TOP OUT.
09/17/2013 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/17/2013 PLUMBING - ROUGH, SOIL Denied 1. CORRECT BACK PITCH ON BLK WATER
2. PROVIDE A WYE PATTERN FITTING FOR FOOT
3. VENT, ALSO, INSTALL CO AND DRAIN FITTING @ ISLAND (OR 10 DRAIN & VENT RISERS)
4. MAX SLOPE ON TRAP ARM IS 1/4" PER FOOT
5. CONNECT TRACER WIRES W/ WATER RESISTANT WIRE NUT
6. REMOVE ANY ROCKS TOUCHING PIPES
09/16/2013 PLUMBING - ROUGH, SOIL Not ready for Inspection