Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/21/2014 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | 1. Remove all rocks and calichi. Piping is to be shaded with clean fill or sand. Piping to be taped at wrench marks. Minimum of 12" of cover. Piping not installed per plan. Provide accurate redlines, and then have them reviewed for code compliance. Will re-open 03035 for shower pan inspection. | |
| 01/21/2014 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 01/13/2014 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/13/2014 | PLUMBING - GAS PRESSURE TEST | Denied | FIRE PIT NEEDS 1" GASLINE "145' FROM METER" |