Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/10/2013 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 10/09/2013 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
| 10/09/2013 | PLUMBING - ROUGH, SOIL | Partial Approval | NO HORIZONTAL DRY VENTING BELOW FIXTURE FLOOD LEVEL. CORRECT BACK SLOPE ON FLOW CONTROL VENT. OK TO COVER OTHER AREAS | |
| 10/08/2013 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/08/2013 | PLUMBING - ROUGH, SOIL | Denied | EACH DRY CENT SHALL RISE CERTICALLY AS SHOWN ON PLAN. FLOW CONTROL VENT AT 45 DEGREES INTO WALL SO THAT ACCESS IS MAINTAINED TO FLOW CONTROL. INSTALL TEST FITTINGS AND TEST THRU SO THAT NO JOINTS ABV SLAB GO UNTESTED. |