Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/22/2013 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/18/2013 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 10/18/2013 | PLUMBING - FINAL | Partial Approval | 1. PROVIDE SEDIMENT TRAP AT WATER HEATER 2. ANCHOR GAS PIPING AT WATER HEATER, RE-INSTALL BONDING CLAMP 3. PVC TUBE COATED FOR UV PROTECTION |
|
| 10/04/2013 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/04/2013 | PLUMBING - FINAL | Denied | GAS LINE UNDER SLAB IS NOT PERMITED. RE-ROUTE GAS LINE AND RE-CALL WITH PRESSURE REST ON ELECTRIC GAS SYSTEM. | |
| 09/23/2013 | PLUMBING - FINAL | Not ready for Inspection | ||
| 09/23/2013 | PLUMBING - FINAL | Not ready for Inspection | WILL NEED ACCESS TO GAS PRESSURE GAUGE TO VERIFY |