Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/02/2014 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 04/29/2014 |
BUILDING - FINAL |
|
Denied |
SECURE VAC BREAKERS (BREAK OFF SCREW). SECURE RISER. COMPLETE REQUIRED NOTED CORRECTIONS |
| 04/08/2014 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 04/08/2014 |
BUILDING - FINAL |
|
Not ready for Inspection |
HB VACUUM BREAKERS REQ'D ON HOSE BIBS. WATER HAMMER ARRESTORS REQ'D @ WASHER CONN. SINK DRAIN ARM MAY NOT CHANGE ELEVATION (POINT OF VENT BELOW TRAP WEIR). ALSO, USE DRAINAGE FITTINGS. |