Permit: T13CM04140

Parcel: 141136670


Addresses:

8640 E ESSELMONT DR


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T13CM04140

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/09/2013 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/01/2013 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/01/2013 MECHANICAL - FINAL Denied P TAPE IS NOT AN APPROVED SUPPORT - ALSO, COPPER MAY NOT TOUCH METAL.
CORRECT SLOPE OF CONDENSATE. SUPPORT & SECURE DRAIN PIPE.
07/26/2013 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/26/2013 MECHANICAL - FINAL Denied SUPPORT CONDENSATE PIPING. ALSO, PROVIDE PROPER ALIGNMENT OF FITTINGS AND PVC PRIMER ON ALL SOLVENT CEMENT JOINTS. SUPPORT LINES SET, CORRECT GAPS IN DAMAGE TO INSULATION. VENT TOUCHING WOOD AT ROOF. INSTALL CARBON MONOXIDE DETECTOR.