Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/22/2013 |
FRAMING |
|
Approved |
IVRS - Inspection :* |
| 07/19/2013 |
FRAMING |
|
Not ready for Inspection |
1. 1/2" lag bolts required for 2"X2" stl. post. |
| 07/17/2013 |
FRAMING |
|
Not ready for Inspection |
1. A-1 detail one. Bottom track anchor metal studs to floor at 34" on center with one and a half inch power driven fasteners. Show that the correct fastener was used. A-1 detail two. 2"X2" steel post at 48" on center. half inch lag bolts required. Bolts installed are not tight. A-1 A shows partition extending one inch past the existing floor sink. Plumbers tape is not an approved strap. Support copper stub outs. |
| 07/12/2013 |
FRAMING |
|
Not ready for Inspection |
1. Partition not constructed per plan. See sheet A-1 Details #01 and #02. Isolate copper from the metal studs. Support copper in the walls. Support copper stub outs. |