Permit: T13CM03754

Parcel: 12217384A


Addresses:

3145 E LEE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/15/2013 FRAMING Approved IVRS - Inspection :*
10/11/2013 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/11/2013 FRAMING Denied 1. PROVIDE POST CAPS PER DETAIL 12/0-1
2. PROVIDE BLOCKING FOR GRAB BAR INSTALLATION BATHROOMS
3. SECURE ALL WIRING 6" FROM BOXES THROUGHOUT
4. REINFORCE WINDOWS
5. SUBMIT AS BUILT TO E-1 ADDED ON LIGHTS THROUGHOUT
6. SECURE 90 VENTS THROUGH ROOF
7. FIRE BLOCK DROPPED CEILING IN BATHROOM
8. FIRE CAULK PENTRATIONS THROUGH FIRE WALOL
9. RELOCATE ANY SMOKE ALARMS WITHIN 36" FORCED AIR REGISTER
09/25/2013 FRAMING Partial Approval WALL SHEATHING OK TO COVER
09/25/2013 FRAMING Partial Approval OK TO COVER SHEATING