Permit: T13CM03530

Parcel: 141153540

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/10/2013 FRAMING Approved IVRS - Inspection :*
07/03/2013 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/03/2013 FRAMING Denied MINIMUM 2 DIAGONAL BRACES PER WALL PER "D" OF A-1
07/02/2013 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/02/2013 FRAMING Denied - PARTITION WALLS NOT TO BE TIED TO T-RAIL OF SUSPENDED CEILING
- BRACE ALL WALLS FROM RAFTERS PER "D" OF A-1