Permit: T13CM03070

Parcel: 14023182C

Inspection Status: Denied

Inspection History: ELECTRIC - RECONNECT

Permit Number - T13CM03070

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Denied

Date Description Inspector Results Comments
05/30/2013 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/30/2013 ELECTRIC - RECONNECT Denied 1. BARE WIRES HANDING OUT OF BROKEN PORCH LIGHT
2. BREAKER COVER AT METER MISSING
3. PROVIDE MINIMUM 3' CLEARANCE IN FRONT OF PANEL (UNABLE TO OPEN PANEL)
4. WIRING HANGING OUT OF CEILING
5. SMOKE ALARMS REQUIRED IN BEDROOMS AND AREAS LEADING TO BEDROOMS. ALARMS TO BE MINIMUM 3' FROM SUPPLY AIR
6. DEAD FRONT MISSING FROM EXTERIOR PANEL
7. PROVIDE COVER OVER EXPOSED ROMEX AT INTERIOR PANEL (SHEET ROCK)