Permit: T13CM03058

Parcel: 136082880


Addresses:

9612 E 33RD ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/29/2013 PLUMBING - FINAL Approved IVRS - Inspection :*
05/28/2013 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/28/2013 PLUMBING - FINAL Denied REMOVE TAPE FROM VENT CONNECTIONS - SECURE W/ SCREWS. CORRECT KINKS IN WATER FLUXES. CHECK RELIEF DRAIN FOR LEAKS. PLUG DRAIN PAN. INSTALL CM DETECTOR PER INSTRUCTIONS; IN HALLWAY. INSTALL PLUG AT STOVE VALVE IF NOT INSTALLING STOVE. PROVIDE ROOF ACCESS ALSO ELECTRICAL BONDING.
05/24/2013 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
05/21/2013 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
05/21/2013 PLUMBING - FINAL Not ready for Inspection WH REPLACED W/OUT PERMITS REQUIRES; PIPE RELIEF DRAIN TO APPROVED LOCATION; INSTALL A NEW GAS FLEX, SECURE & ALIGN VENT CONNECTOR; INSTALL PAN, INSTALL CARBON MONOXIDE DETECTOR; INSTALL FLASHING @ ROOF PSN; REPLACE MISSING SUPORTS ON ROOF.