Permit: T13CM02961

Parcel: 12112399F


Addresses:

1660 N BEVERLY AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/31/2013 PLUMBING - FINAL Approved IVRS - Inspection :*
05/23/2013 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
05/23/2013 PLUMBING - FINAL Partial Approval LEFT GAS CARD
PROVIDE DOUBLE VENT ALL THE WAY THROUGH THE ROOF WITH AN APPROVED CAP FOR WALL HEATER
RECALL FOR FINAL INSPECTION
05/16/2013 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/16/2013 PLUMBING - FINAL Denied 14 PSI TEST IS OK
REPLACE THE T & P0 RELIEF VALVE ON WATER HEATER. REPAIR THE DAMAGED DRAFT DIVERTER ON WATER HEATER. PROVIDE A PRIMARY SOURCE OF HEAT. PORTABLE ELEC HEATERS ARE ONLY TO BE USED AS SUPPLEMENTARY HEAT.
OK TO BACKFILL TRENCH