Permit: T13CM02808

Parcel: 13323190A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T13CM02808

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/08/2013 PLUMBING - FINAL Approved IVRS - Inspection :*
10/07/2013 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/02/2013 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/02/2013 PLUMBING - FINAL Denied COMPLETE WORK. SOV AND CHECK SHOWN @ WH RECIRC PUMP. VACUUM RELIEF VALVE REQUIRED PER 504.2. REPLAE IMPROPERLY INSTALLED ABS W/ PVC GLUE. PROTECT PLASTIC FROM UV RAYS. SUPPORT BOTH ENDS OF VAC PUMP EXHAUST. PROVIDE LISTED AND PROPERLY SIZED PIPE SUPPORTS. DUCT STRAP OK FOR EXP TANK. MAKE CLEAN-OUTS ACCESSIBLE. REPLACE DAMAGED PLUGS, INSTALL PLUGS LISTED FOR SCREW. UNION REQUIRED AT BACKFLOW ASSEMBLY FOR SERVICING. SEE IPC 504.2, 303.2.
09/26/2013 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*