Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2013 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 07/19/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 07/19/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | OK TO COVER ELEC ON INTERIOR | |
| 07/17/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 07/17/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | NEW CIRCUITS AND PANEL ON SEPARATE PERMIT ITEM 2, 4, 6, 8, 9, STILL NOT CORRECTED |
|
| 06/07/2013 | ELECTRIC - INTERMEDIATE | Denied | 1. KITCHEN OUTLET WIRING AS FOLLOWS: 2-20 AMP APPLIANCE CIRCUITS RANGE BOX APPROVED ANY COUNTER SPACE OVER 12" REQUIRES GFCI OUTLET ANY PENINSULA REQUIRES OUTLET ANY MICROWAVE, REFRIGERATOR OUTLETS TO BE DEDICATED 2. REAR PORCH FAN WIRING NOT TO CODE REPLACE 3. INSTALL HARD WIRED SMOKE ALARM CIRCUIT TO HALLWAY AND BEDROOMS INTERCONNECTED 4. RECOMMEND PANEL UPGRADE FOR EXTRA CIRUITS 5. SECURE ALL WIRING TO CODE 6. CEILING FANS REQUIRE APPROVED BOXES 7. COMBUSTION RELIEF 100 CU INCHES WATER HEATER 8. TPR LINE TO EXTERIOR 9. EXPOSE PORCH FOOTERS TO VERIFY DEPTH |
|
| 05/30/2013 | ELECTRIC - INTERMEDIATE | Denied |