Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2013 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/08/2013 | PLUMBING - FINAL | Approved | 12 PSI TEST IS OK LEFT GAS CARD CORRECTIONS HAVE BEEN MADE OK TO BACKFILL TRENCH |
|
| 05/06/2013 | PLUMBING - FINAL | Not ready for Inspection | 1. Reducing a 3/4" water line to 1/2", then back to 3/4" not permitted. @. Water lines installed in or on an exterior wall to be insulated. 3. Black iron pipe not permitted on potable water systems. 4. Metal tape on "B" vent, not permitted. 5. Tand P relief drain to extend down to the floor. 6. 3/8" i.d. X3' long undersized for the water heater. 7. Cap off open ended gas valves. 8. Expose all repaired work. 9. Repair all wall penetrations. 10. Water heater to sit 3" above surrounding grade. May not be a complete list. |