Permit: T13CM02625

Parcel: 141097400


Addresses:

8062 S NAUTILUS DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/17/2013 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/13/2013 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
06/13/2013 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection PRIOR INSP LIST NOT COMPLETED
06/06/2013 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/06/2013 EXT METAL CLIPS/EXT SHEATHING Denied - ANCHOR BOLTS NEEDED WITHIN 12" OF PLATE SPLICES EXTERIOR CLOSET WALL OF BEDROOM #2
- COIL STRAP TOP PLATES AT TRAYED CEILING LINE WEST WALL PER 9/S5.1
- POST CAPS NEEDED BACK PATIO
- COIL STRAP BEAM TO TRIMMERS PER 6/S5.1 AT HOUSE