Permit: T13CM02624

Parcel: 118050890


Addresses:

1846 W SAN JUAN TR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/03/2013 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/21/2013 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/21/2013 ELECTRIC - FINAL Denied SEE NOTES LAST INSP 5-17-13
NO RISER CONDUCTORS
05/17/2013 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
05/17/2013 ELECTRIC - FINAL Not ready for Inspection 1. PROVIDE #4 GROUND WIRE TO TWO GROUND RODS, ROD SPACING MIN. 6' WATER AND GAS ARE TO BE BONDED
2. PROVIDE TWO POINTS OF CONNECTION (STRAP) TO BUILDING AT RISER
3. MAST OVER 24" ARE TO HAVE GUYED (?) WIRE SUPPORTS