Permit: T13CM02581

Parcel: 120076050

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/22/2014 BUILDING - FINAL Approved IVRS - Inspection :*
04/11/2014 BUILDING - FINAL Partial Approval IVRS - Inspection :*
04/11/2014 BUILDING - FINAL Partial Approval NOTES 1 & 7 FROM PREVIOUS - NOTES 2, 3, & 4 HOME INCLUSIVE
03/03/2014 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/03/2014 BUILDING - FINAL Denied 1. COMPLETE GRADING & PARKING AREAS
2. POST ADDRESS VISIBLE FROM PENNSYLVANIA ST
3. 90 FITTING @ CONDENSATE LINE
4. PAINT ROOF VENTS ABS
5. PROVIDE SAFE ACCESS TO ROOFTOP UNITS
6. ARC FAULT PROTECT BEDROOM CIRCUITS
7. A UNIT 2 KITCHEN GFCI OUTLETS 2-20 AMP CIRCUITS
8. PROVIDE PANS @ WATER HEATERS OR RR (?) LINE TO EXTERIOR
9. REMOVE GAS FROM PLAN OR BUILD TO PLAN
02/28/2014 BUILDING - FINAL Partial Approval IVRS - Inspection :*
02/28/2014 BUILDING - FINAL Partial Approval TRIED TO CALL 603-793-2065 AS PER REQUEST - COULD NOT GET THROUGH - PLEASE RESCHEDULE INSPECTION. OK YARD WATERLINE, GASLINE??