Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/21/2013 FRAMING Approved IVRS - Inspection :*
10/17/2013 FRAMING Partial Approval IVRS - Inspection :*
10/17/2013 FRAMING Partial Approval 1. BLOCK REGISTER BOOTS (?) 3-SIDES
2. COMMON WAlL TO UNDERSIDE OF ROOF SHEATING
3. BLOCKING PER HOME INCLUSIVE FUTURE SOLAR NOT ON PLAN
09/23/2013 FRAMING Not ready for Inspection IVRS - Inspection :*
09/23/2013 FRAMING Not ready for Inspection 1. NAIL ALL HOLD DOWNS DOUBLE STUD @ OSB 6" OC
2. RETROFIT ALL HOLD DOWNS NOT INTO DOUBLE STUD
3. 2 AB'S PER BRACE PANEL
4. COMPLY WITH DETAIL CABLE END TRUSS
5. DIAPHRAM NAILING 8D @ 6" OC DETAIL 1
6. PROVIDE STAMPED APPROVED COT TRUSS CALCS
7. ALL BRACED PANELS TO REACH TOP/TOP PLATE
8. PER SECTION A-A MISSING H-25 CLIPS REAR PORCH
9. NAIL PROTECT KITCHEN DRAINS