Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2013 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/17/2013 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/17/2013 | FRAMING | Partial Approval | 1. BLOCK REGISTER BOOTS (?) 3-SIDES 2. COMMON WAlL TO UNDERSIDE OF ROOF SHEATING 3. BLOCKING PER HOME INCLUSIVE FUTURE SOLAR NOT ON PLAN |
|
| 09/23/2013 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 09/23/2013 | FRAMING | Not ready for Inspection | 1. NAIL ALL HOLD DOWNS DOUBLE STUD @ OSB 6" OC 2. RETROFIT ALL HOLD DOWNS NOT INTO DOUBLE STUD 3. 2 AB'S PER BRACE PANEL 4. COMPLY WITH DETAIL CABLE END TRUSS 5. DIAPHRAM NAILING 8D @ 6" OC DETAIL 1 6. PROVIDE STAMPED APPROVED COT TRUSS CALCS 7. ALL BRACED PANELS TO REACH TOP/TOP PLATE 8. PER SECTION A-A MISSING H-25 CLIPS REAR PORCH 9. NAIL PROTECT KITCHEN DRAINS |