Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T13CM02392

Parcel: 110113610


Addresses:

2480 N SWAN RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T13CM02392

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/11/2013 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/10/2013 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/30/2013 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
08/30/2013 PLUMBING - INTERMEDIATE Partial Approval DWV TEST THRU ROOF OK. PROVIDE SUPPORTS AS REQUIRED. PIPE INSULATION IN WALLS; OK TO COVER WALLS
08/26/2013 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
08/23/2013 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
08/22/2013 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/22/2013 PLUMBING - INTERMEDIATE Denied PLASTIC MAY NOT BE TESTED W/ AIR EVEN PEX. WIPE OFF EXCESS FLUX. TAPE DOES NOT HOLD BACK SEWER GASSES. PLUG BOTH SIDES - GET PLUGS IN THOSE OPENINGS NOW! WILL REFEE NEXT TIME