Permit: T13CM02262

Parcel: 131052130


Addresses:

5402 E 30TH ST 0B

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/26/2013 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
04/25/2013 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/22/2013 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
04/22/2013 PLUMBING - GAS PRESSURE TEST Partial Approval TEST OK. CORRECT VENTING & RELIEF VALVE. OK TO COVER PIPING
04/17/2013 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/17/2013 PLUMBING - GAS PRESSURE TEST Denied CORRECT VENTING; TYPE B REQ TERMINATION LARGER APPLIANCE IS REQUIRED TO BE THE LOWER CONNECTION AT COMMON VENT. SECURE ALL JOINTS W/ SCREWS. PIPE RELIEF VALVE. CARBON MONOXIDE DETECTOR REQUIRED.