Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T13CM02262
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/26/2013 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 04/25/2013 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/22/2013 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* | |
| 04/22/2013 | PLUMBING - GAS PRESSURE TEST | Partial Approval | TEST OK. CORRECT VENTING & RELIEF VALVE. OK TO COVER PIPING | |
| 04/17/2013 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/17/2013 | PLUMBING - GAS PRESSURE TEST | Denied | CORRECT VENTING; TYPE B REQ TERMINATION LARGER APPLIANCE IS REQUIRED TO BE THE LOWER CONNECTION AT COMMON VENT. SECURE ALL JOINTS W/ SCREWS. PIPE RELIEF VALVE. CARBON MONOXIDE DETECTOR REQUIRED. |