Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2013 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/06/2013 | PLUMBING - FINAL | Not ready for Inspection | DRIP AT 3/8 CONN ELECTRICAL OUTLET REQUIRED |
|
| 05/22/2013 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 05/22/2013 | PLUMBING - FINAL | Partial Approval | EXT WEATHER PROOF OUTLET REQUIRED | |
| 05/16/2013 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/16/2013 | PLUMBING - FINAL | Denied | EQUIPMENT DISCHARGE IS REQUIRED TO TERMINATE INSIDE OF PROPERTY CORRECT LEAKS LOW VOLTAGE WIRE IS NOT LISTED FOR WALL PENETRATION PVC NOT PROPERLY INSTALLED |
|
| 04/24/2013 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/24/2013 | PLUMBING - FINAL | Denied | PVC DOMESTIC WATER REQ 12" MIN COVER. ALL PVC REQ PRIMER. EXPOSED PVC DRAIN REQ SUPPORT AND UV PROTECTION ALSO SECURE. PROTECT CANAL BANK FROM EROSION. INSTALL A PROTECTED OUTLET AT EQUIPMENT LOCATION SEAL WALL PENETRATION CHECK REGULATOR PRESSURE |