Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T13CM02027
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/30/2013 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/22/2013 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* | |
05/22/2013 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | EQUIVILANT NEEDED FOR HOLD DOWN AT SOTHWEST CORNER NOT MEETING BURIAL DEPTH IN CONCRETE | |
05/21/2013 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
05/21/2013 | EXT METAL CLIPS/EXT SHEATHING | Denied | -BLOCK PARALLEL TRUSS TOP CHORD PER 9/55.2 -RSP4'S NEEDED AT BACK PARAPHET -STRAP INTERIOR BEAM PER 6/55.1 -AB'S 32" O.C. FOR #5 SHEAR WALLS -SHEAR NEEDED ON NORTH SIDE OF GARAGE -LET IN BRACE EXTERIOR TO CODE |