Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T13CM02027

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/30/2013 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/22/2013 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
05/22/2013 EXT METAL CLIPS/EXT SHEATHING Partial Approval EQUIVILANT NEEDED FOR HOLD DOWN AT SOTHWEST CORNER NOT MEETING BURIAL DEPTH IN CONCRETE
05/21/2013 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/21/2013 EXT METAL CLIPS/EXT SHEATHING Denied -BLOCK PARALLEL TRUSS TOP CHORD PER 9/55.2
-RSP4'S NEEDED AT BACK PARAPHET
-STRAP INTERIOR BEAM PER 6/55.1
-AB'S 32" O.C. FOR #5 SHEAR WALLS
-SHEAR NEEDED ON NORTH SIDE OF GARAGE
-LET IN BRACE EXTERIOR TO CODE