Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T13CM01918
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/06/2013 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
09/06/2013 | REINFORCED MASONRY PRE-GROUT | Approved | WALLS TOPPED-OUT AT 23' 8"; PILASTERS AT 4' 4" - OK TO GROUT PROGRESS AREAS | |
09/05/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/05/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | EAST WALLS AT 21' - OK TO GROUT #4 VERTICAL BARS IN PLACE AT 32" ON CENTER | |
09/04/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/04/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALL AT 22' (TOP-OUT SOUTH WALL) WEST & NORTH WALL AT 21' **NOTE:** SW WEST AREA ON WEST WALL - BOND BEAM PLACED FOLLOWING RACKED LEDGER NOT AS PER DETAIL #302, PAGE S601 (APPROX 25') |
|
08/28/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/28/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 17'0" GL: 3/A.5-A.7; GL: 3/B.25-C; GL: C/1-3 (PILASTERS ONLY - 24" ABOVE LINTEL) - OK TO GROUT PROGRESS AREAS. | |
08/27/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/27/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS AT 17' GL: A/1-3; 3/C.5; GL: 1/A-C - OK TO GROUT PROGRESS AREAS D-6 | |
08/22/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/22/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CONTINUOUS CMU WALLS AT 13' - OK TO GROUT PROGRESS AREAS | |
08/20/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/20/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CONTINUOUS CMU WALLS AT 4' 8" - 9' - OK TO GROUT PROGRESS AREAS | |
08/15/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/15/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | STEM WALL (EAST WALL) GL: C/1.5-2, 2.25-2.5 ADDITONAL #8 REBAR IN EAST & WEST BEAM BEARING AREAS GL: 2/C, A/2 - OK TO GROUT PROGRESS AREAS |
|
08/14/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/14/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CONTINUOUS CMU WALLS AT 0'-5' A.F.F.E. (EXCEPT FOR BEAM BEARING AREAS AT GL: 2/A & 2/C) (DETAIL #1, PAGE SO21) OK TO GROUT PROGRESS AREAS |