Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/22/2013 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 04/18/2013 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/18/2013 | ELECTRIC - RECONNECT | Partial Approval | 1) HALL SMOKE DETECTOR TOO CLOSE TO WALL 2) FINISH #3,5 AND 7 PREVIOUS INSTPECTION *NOTE OPEN SPLICES IN CARPORT SHEDS |
|
| 04/04/2013 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING LIGHT FIXTURE AND EXPOSED CONDUCTORS (MISSING ELECTRICAL BOXES) 2) INSTALL SMOKE DETECTORS TO MANUFACTURES INSTRUCTIONS MISSING SMOKE DETECTORS 3) WIRING OUTDOORS NOT CODE COMPLIANT AND DETERIOATED 4) NEW KITCHEN RECEPTACLE TO BE GFCI PROTECTED 5) GROUNDED RECEPTACLES ON NON GROUNDED CIRCUITS 6) SUPPORT AND SAL WITH APPROVED DEVICE, RACEWAY ON TOP OF SERVICE PANEL 7) EXTENTION CORD NOT TO BE USED FOR PERMENT WIRING-OUTDOORS |