Permit: T13CM01822

Parcel: 113051700


Addresses:

3437 N WILSON AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/19/2014 FRAMING Approved
05/14/2014 FRAMING Partial Approval ADD STUDS UNDER DEN NORTH/SOUTH GLUELAM
05/07/2014 FRAMING Not ready for Inspection 1. Framing cant be approved until after plumbing, electrical, approvals. 2. ABS requires a water test. Vertical piping not supported. Overhead horizontal piping not supported. International codes do not recognize horizontal dry vent. (At upstairs water closet.) ABS shims not approved waste line support. 3. Under floor sleeve for gas at island does not meet code. 4. All mechanical registers to be supported on three sides. All drainage piping to have grade. Vertical X horizontal change of direction in waste piping to be a sweep. 5. Yardwater covered.