Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/16/2013 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/28/2013 | PLUMBING - FINAL | Not ready for Inspection | permits required for other work obviously being done at this residence spoke with owner afterwards to discuss this issue and she will persue it with her contractors |
|
| 06/28/2013 | PLUMBING - FINAL | Not ready for Inspection | PERMITS ARE REQUIRED FOR ALL ELECTRIC, MECHANICAL, & PLUMBING THAT WAS PERFORMED. INSPECTIONS WILL BE NEEDED ON ALL WORK PEFORMED. OUR RECORDS INDICATE THAT THE ONLY PERMIT OBTAINED WAS FOR GAS PIPING | |
| 06/06/2013 | PLUMBING - FINAL | Not ready for Inspection | 1. Require shut off valve at cold inlet. PVC is not approved for hot water. House gas to be tested to ten pounds. | |
| 06/04/2013 | PLUMBING - FINAL | Partial Approval | GAS FLEX CONNECTOR CANNOT PASS THROUGH THE ENCLOSURE. SINGLE WALL VENTING NOT ALLOWED OUTDOORS. PROVIDE A T & P DRAIN. | |
| 06/03/2013 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* |