Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T13CM01153

Parcel: 129130760


Addresses:

825 E 31ST ST

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
08/23/2013 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
08/21/2013 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/21/2013 REINFORCED MASONRY PRE-GROUT Denied 1. PROVIDE 1 1/2" CLEARANCE @ BOND BEAM
2. VENTS 1 1/2" FROM TOP PLATE
08/20/2013 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
Lock up dogs in the yard.| 910*
08/20/2013 REINFORCED MASONRY PRE-GROUT Denied DOGS IN YARD - NO MSG - RESCH INSPECTION
08/14/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*