Permit: T13CM01069

Parcel: 112071830


Addresses:

2525 E WATER ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/05/2013 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
02/28/2013 PLUMBING - INTERMEDIATE Not ready for Inspection 1. Water heater requires a permit. Washer supplys require hammer arrestors. Water piping installed in or on an exterior wall to be insulated. Piping installed outside above grade to be insulated and UV protected, and protected from mechanical damage.. Remove the retaining screws from the AVBs. Pan not required under water heater, drain not run, or plugged. Interior walls covered before inspection.