Permit: T13CM00547

Parcel: 11504520A


Addresses:

1011 N TYNDALL AV


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T13CM00547

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
07/30/2014 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
06/19/2014 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/19/2014 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND LIFT ON TRASH ROOM
06/18/2014 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/26/2014 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/25/2014 REINFORCED MASONRY PRE-GROUT Partial Approval SW CORNER 16' LIFT OK
02/24/2014 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/24/2014 REINFORCED MASONRY PRE-GROUT Partial Approval 16' LINE A/7.2-9.2, 9.2/A-B
02/21/2014 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/20/2014 REINFORCED MASONRY PRE-GROUT Partial Approval SOUTHWEST CORNER 12'
02/18/2014 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/18/2014 REINFORCED MASONRY PRE-GROUT Partial Approval GROUND LEVEL 1ST LIFT SOUTHWEST CORNER & 8' LIFT ON WESTSIDE COLUMNS
12/12/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL LINE A/1-28 20' TO 24'
12/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval TOP OUT AT NW CORNER LEVEL 1
11/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11/20/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 2 STAIR #1 8'-12' LINE 6.8/A-A.4 4'-12' A/5-5.5 18'-24'
11/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval
11/08/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 4' WEST SIDE LEVEL 2 & TOP OUT AT MECH ROOMS LEVEL 1
11/05/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11/05/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 1 12'-16' LOADING DOCK LINE 6.6/C.2-D 8'-10'
11/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11/01/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LOADING DOCK 8'-12' ROOM #126-127 8'-12' LINE A/5-5.5, 5.5/A-A.3
10/31/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 1 LOADING DOCK WALL 4' TO 8' LINE A/5-5.5 5.5/A.3 8' LIFT
10/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 1 LINE A/5.5 7.2-9 4' LIFT 5.5/A-A.3 RM# 113 & STAIR #1. RM# 114 4'-8' LIFT. LINE 6.6/C.2-E.11
10/25/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/25/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 1 LINE F/1-5.8 1ST LIFT
LEVEL STAIR #3 TRASH SHUTE 8'-12' LOADING DOCK WALLS 8'12'
10/22/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 2 LINE A/2.5-5 2ND LIFT, STAIR #3 TRASH CHUTE
10/18/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND FLOOR GARAGE BERRIER WALL OK TO 4' ABOVE CONCRETE
10/18/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND FLOOR TRASH SHOOT PRE-GROUT OK TO 4'
2ND FLOOR STAIRWAY #3 OK TO 4'
10/16/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/15/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 1/A-A.5 LECEL 1-2 16'-20' - 1/A.5-G2 20' - 22' LEVEL 1-2
10/14/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LINE 1/A.5-6 16'-20'; 1/A-A.5 12'-16'
10/09/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LINE 1/A.5-G.2 2ND LEVEL 1ST LIFT
10/08/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 1ST LIFT 2ND LEVEL LINE 1/B.5-G; G/2-6.6; 8/B-E.8
10/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/03/2013 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 1 LINE 1/B-G.2, F/1-2.5, 2.5/F-F.8 2ND LIFT OK
10/02/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/01/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 1ST LEVEL LINE 1/A.4-6.2, E.8/1-6.6, 6.6/C.2-E.8, B/7.5-9, 4' LIFT