Permit: T13BU01285

Parcel: 11917048B


Addresses:

3756 S 6TH AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/01/2014 MECHANICAL - FINAL Approved IVRS - Inspection :*
01/13/2014 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
01/13/2014 MECHANICAL - FINAL Not ready for Inspection 1. REMOVE GAS OVEN - NOT UNDER HOOD
2. REMOVE FRYER - NOT WITHIN HOOD PARAMETERS
3. ALL TYPE 1 HOOD EXHAUST TO HAVE GREASE RECEPTORS, HINGE KITS, GASKETED FLANGES, DISCONNECTS, & APPROVED WIRING METHODS
4. DISCONNECT OR REMOVE COOLER WITHIN 10' OF EXHAUST SYSTEM