Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T12PL00170

Parcel: 107010030

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T12PL00170

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/17/2012 PLUMBING - FINAL Approved
02/15/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) APPLIANCE CONNECTOR IS NOT A MOBILE HOME CONNECTOR, MUST SAY MOBILE HOME CONNECTOR ON LISTING
2) OK TO COVER
02/14/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) OK PRESSURE
2) FITTINGS AND WRENCH MARKS TO BE PRIMED AND TAPED HALF OVERLAPPED DBL WRAPPED. REQUIRE SHUT OFF AND MOBILE HOME CONNECTOR
02/10/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) MINIMUM DEPTH FOR GAS IN A MOBILE HOME PARK 18"
2) FITTINGS AND WRENCH MARKS TO BE PRIMED AND TAPED HALF OVERLAPPED DBL WRAPPED. REQUIRE SHUT OFF AND MOBILE HOME CONNECTOR
3) REQUIRES 10 POUND TEST