Permit: T12PL00146

Parcel: 118061610


Addresses:

1919 W MISTLETOE CI

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/06/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
01/31/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) RESECURE WATER HEATER ENCLOSURE
2) VENT CONNECTOR NOT CONNECTED
3) REQUIRE 6" CLEARANCE FROM COMBUSTIBLES FOR VENT CONNECTOR
4) PROPER VENTING ? "B" VENT OUTDOORS
5) REQUIRE FLASHING OF ROOF PENETRATION
6) SUPPORT THE PIPING OFF OF THE ROOF
7) WATER HEATER AND FURNACE REQUIRE SEDIMENT TRAPS
8) SUPPORT THE VERTICAL PIPING ON THE WALL