Permit: T12PL00082

Parcel: 122070750


Addresses:

4401 E WAVERLY ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T12PL00082

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/26/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
01/23/2012 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SINGLE WALL REQUIRED 6" CLEARANCE AT ROOF
2) SECURE B VENT
01/18/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NEW FURNACE REQUIRES A PROPER CONNECTION TO BE VENT AND A NEW GAS FLEX-APPEARS TO HAVE BEEN INSTALLED WITHOUT PERMIT
2) CAP ABANDON GAS PIPING IN HOME
3) INSTALL A VENT FOR THE GAS DRYER OR REMOVE PIPING
4) SECURE AND SEAL FLASHINGS
5) ATTACH BOND WIRE