01/31/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
01/18/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) BLACK IRON PIPE IS NOT PERMITTED BELOW GRADE TAPING IS LIMITED TO SHORT SECTIONS STRIPPED FOR THREADING AND FITTINGS OR PIPE MARRED BY WRENCHES
2) PROVIDE SAFE ACCESS TO ROOF
3) ROOF TOP GAS TO BE SUPPORTED OFF THE ROOF
4) WATER HEATER VENT NOT APPROVED
5) REMOVE METAL TAPE AND SHOW THE VENT CONNECTOR IS MADE UP PROPERLY