Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/22/2012 | SIGN SITE REVIEW | Approved | ||
| 08/18/2012 | SIGN SITE REVIEW | Correction Required | Sign review by Heather Thrall contact me at Heather.Thrall@tucsonaz.gov or 837-4951 if you have questions, and note that responses to this review may generate additional code related comments: 1) Clarify vertical clearance under portion of wall sign "B" that extends past the wall. This portion of the sign is over a pedestrian area and must have a minimum of 8' vertical clearance over sidewalk. (3-80.H.6.C) 2) Provide better detailed drawing of sign "B" to show how arrow is constructed - is it all one shaped aluminum cabinet or is it just acrylic mounted to cabinet face. Elevation view shows two arrows (one shadow effect) is this a shadow on the drawing or is this another solid piece of material? Sign Code Section 3-18.B.4 & 5 3) specify light source for sign "B" in construction drawing - fluorescent or LED? Sign code Section 3-18 B.4 & 5 4) Specify contractor who is manufacturing the signage, whether it's UL rated, and who is installing the signage - two different sets of contractor drawings in packet. Written permission required to use another contractor's drawing. Sign Code Section 3-18. A.8. |