Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/07/2012 | ELECTRIC - FINAL | Denied | GET ELECTRICIAN TO GO THRU BUILDINGS 1 AND 2 B4 CALLING INSPECTION BACK IN | |
| 10/09/2012 | ELECTRIC - FINAL | Denied | 1. SEAL HOLES IN EXTERIOR BOX WITH APPROVED APRTS BOTH UNITS 2. SMOKE DETECTOR TO BE 3' FROM FAN AND DUCTS 3. NM CABLES ON SIDE OF HOUSE INSTALLED CODE COMPLAINT 4. ONLY ONE NEUTRAL CONDUCTOR TO 5. MISSING DEADFRONT ON LARGE SERICE FILL UNUSED OTHER PANEL 6.ADDRESSING PAINTED OVER CAN NOT READ 7. CONNECT ALL GROUND CONDUCTOR BACK BUILDING #2 8. GROUNDER RECEPTABLES ON NON GROUNDED CITRCUITS |
|
| 09/12/2012 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ELECTRICAL CONDUIT IN FRONT YARD NO BURIED TO PROPER DEPTH 2) ELE. OUTLET AT FRONT DOOR NEEDS PLUG. (ALL EXTERIOR) 3) FRONT PORTCH LIGHT NEEDS SAFETY GLOBE. (LAUNDRY ALSO) 4) WIRING HANGING OUT OF WALL IN LAUNDRY 5) BARE ROMEX ON EXTERIOR WEST WALL 6) J-BOX AT GUEST HOUSE NEEDS PLUGS (EXTERIOR) 7) BARE WIRING EXPOSED AT REAR MASTER BEDROOM 8) ALL BEDROOMS TO HAVE SMOKE ALARM ( INCLUDING GUEST) |