Permit: T12EL00418

Parcel: 111042240

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/13/2012 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/16/2012 ELECTRIC - FINAL Not ready for Inspection 1) INSTALL SMOKE DETECTORS PER MANUFACTURERS SPEC'S, MUST BE AT LEAST 3 FT FROM REGISTER
03/14/2012 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) SMOKE DETECTORS TO BE PER MANUFACTURES INSTRUCTIONS, TO CLOSE TO DUCT WORK
03/01/2012 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OUTDOOR RECEPTS MUST BE GFI PROTECTED
2) PROVIDE A SMOKE DETECTOR IN EACH BEDROOM AND 1 OUTISE THE BEDROOMS