Permit: T12EL00285

Parcel: 113091020


Addresses:

857 E SEQUOYAH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/28/2012 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/15/2012 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FINISH #3 AND 8 PREVIOUS ITEMS
2) FILL UNUSED OPENING IN BOX WHERE WIRE REMOVED (DINNING)
02/03/2012 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING WEATHER PROOF COVER IRRIGATION RECEPT
2) SECURE AND PROTECT UF CABLES BACK OF HOUSE
3) MAINTAIN WORKING SPACE AT SERVICE
4) BREAKERS AT GARAGE SUB PANEL NOT TO MANUFACTURE
5) NEED SMOKE DETECTOR IN HALL
6) INSTALL SMOKE DETECTORS IN BEDROOMS PER MANUFACTURES INSTRUCTIONS
7) GROUNDED RECEPTS ON NON GROUNDED CIRCUITS
8) CLOSET FIXTURES NOT CODE COMPLIANT
9) BATHROOM RECEPT TO BE GFCI PROTECTED
10) REPLACE KITCHEN RECEPTS TO BE GFCI PROTECTED
11) ? LIGHT NOT TO BE ZIP CORD-INSTALL USING APPROVED METHODS