Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T12EL00274
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/16/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
02/28/2012 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) FINISH CONDUIT STRAPS 2) RECEPT COVERS TO BE WEATHER PROOF WHETHER PLUGGED INTO OR NOT 3) FINISH #3 LAST INSPECTION |
|
02/03/2012 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OUTDOOR BOX NOT WEATHER RESISTANT 2) CONDUIT FITTING NOT FOR OUTDOOR USAGE-NOT WEATHER RESISTANCE 3) MAINTAIN WORKING SPACE AT SERVICE 4) EXPOSED NM CABLE ON EXTERIOR 5) GROUNDED RECEPTS ON NON GROUNDED WIRING 6) EXPOSED NM CABLE SIN CUPBOARDS 7) PLEASE VERIFY IF BACK BLDGS ARE POWERED OFF OF THIS UNIT-NUMEROUS CODE COMPLIANT ISSUES ON THOSE BLDGS |