Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 02/09/2012 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. NEED 2ND GROUND ROD 2. STRAP CONDUCTOR TO BUILDING 3. SEPERATE GROUNDS + NEUTRALS AT SUB PANEL 4. HAVE MULTIPLE LOG TERMINATIONS 5. INSTALL SMOKE DETECTOR PER INSTRUCTIONS |
|
| 02/02/2012 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* #4: 1) NEED SMOKE DETECTOR IN BEDROOM 2) NEED BATHROOM GFCI RECEPT 3) LABEL SUB PANELS 4) NUMEROUS NON CODE COMPLIANCE ISSUES WITH SUB PANEL #2: 1) NEED UNIT NUMBER POSTED 2) NEED SMOKE DETECTORS BEDROOMS AND OUTSIDE OF BEDROOMS 3) RECESSED FIXTURE OUTSIDE SHOWER MISSING TRIM 4) MISSING BLANK AT SUB PANEL AND CLEAN EXCESS FOREIGN MATERIAL AND DIRT #1: 1) NEED SMOKE DETECTORS ALL BEDROOMS 2) BATHROOM RECEPT TO BE GFCI |