Permit: T12EL00142

Parcel: 136341540


Addresses:

3401 S MARC DR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/27/2012 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/20/2012 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE WEATHER PROOF COVER PLATES ON EXTERIOR OUTLETS AT SLIDING DOOR AND PANEL
2) PROVIDE BLANK COVER PLATE AT J-BOX BELOW A/C IN EXTERIOR ROOM
3) REMOVE POWER CORD FROM PANEL TO SHED WIRING MUST BE IN CONDUIT
4) REMOVE OPEN CONDUIT (BARE WIRING) FROM J-BOX ABOVE REAR SLIDING DOOR
5) PROVIDE COVER OVER J-BOX IN OLD HEATER CLOSET
6) REMOVE ROMEX TO T.V. OUTLET, IMPROPERLY WIRED
7) PROVIDE SMOKE ALARMS IN EACH BEDROOM (AT LEAST 3' AWAY FROM VENT) AND IN HALLWAY, EXISTING IS BROKEN
8) ALL OUTLETS ARE TO HAVE COVER PLATES
9) REMOVE BARE WIRE CONNECTED TO MOTION LIGHT AT CARPORT