Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T12DV08593

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
03/08/2013 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE:
PROPERTY COMPLIANT @ THIS TIME.
CLOSE/CASE.
12/12/2012 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE:
NON-COMPLIANT ON WORK COMPLETION. NO PERMITS SECURED.
SEE COND.
09/12/2012 INSP - FOLLOW UP CODE ENFORCE Approved RE-VISITED SITE:
MET WITH OCCUPANT ALSO OWNER ON SITE WITH HANDYMAN/HELPER.
607: PANEL BOX. 14 AWG ON 30 AMP BREAKER. ADDED J/BOX WIRING TO SHORT FOR BOX. WIRING RUNS ALONG UNDERNEITH PATIO ROOF, PROTECTED COVERING. RUNS THROUGH STUCCO WALL DESTINATION UNKNOWN.
UTILITY ROOM: OPEN EXPOSED ROMEX COMMING FROM WALL. LIGHT FIXTURE WIRES COMMING FROM WALL, NO BOXES WALLS OPEN NOT PROPERLY SEALED, FIRE PROTECTION.
KITCHEN UTILIZING EXTENSION CORDS FOR 2 LIGHTS, WIRES HAZARDOUSLY SPLICED.
KITCHEN SHOWS OPEN GROUND UNDER TEST.
BEDROOM 1 SINGLE CONVENIENCE OUTLET ADDED ACTUALLY LIVINGROOM. ALSO SHOWS OPEN GROUND, REVERSE POLARITY.
BATHROOM RELOCATED W.O.P. PLUMBING IN WALL STILL OPEN.
THERMOSTAT LOCATED ON EXTERIOR WALL IN KITCHEN.
GAS FIRED COOK STOVE LACKS MECH. VENTILATION.
UNIT 613: PANEL BOX: 30 AMP BREAKER SHOWS 14 AWG.
OPEN CONDUIT AT ROOF LINE. INTERIOR NO SMOKE DETECTOR. ADDED LAMP CORD THROUGH CUPBOARDS TO SUPPLY KITCHEN LIGHT. DINING ROOM CONVENIENCE OUTLET SHOWS REVERSE POLARITY, OPEN GROUND. BEDROOM CONVENIENCE OUTLET SHOWS OPEN GROUND REVERSE POLARITY. FORCE AIR HEATER SHOWS OPEN GROUND. CONVENIENCE OUTLET DOES NOT OPERATE.
SEWER LINE REPLACED, OPEN TO GROUND, NOT PROPERLY INSTALLED OR COMPLETED NO SECURED PERMIT.
REAR UNIT NO ONE HOME NO INSP. REAR UNIT CAN NOT ACCESS ELECTRICAL EMERGENCY DISCONNECT.
N/O/V 30 DAYS
PERMITS REQUIRED.