08/14/2012 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, SUNNYSIDE HIGH SCHOOL, AT THE N/E SECTION OF THE SCHOOL JUST BEFORE A PERSON WOULD ENTER THE PRACTICE FIELDS, THE SCIENCE MODULAR CLASSROOM #3.
FIRE WAS STARTED OUTSIDE THE CLASS ROOM DOOR (JUST WEST OF THE DOOR). DEBRIS IN A PLASTIC GARBAGE CAN WAS STARTED ON FIRE, GARBAGE CAN MELTED, FIRE ENTERED THE MODULAR CLASSROOM BENEATH THE 4 FT BRICK FACADE.
THE BOTTOM PLATE OF THE BUILDING BURNED, 3 FT SECTION, TRAVELED UP THE 2X6 STUDS, FIRE AND SMOKE EXITED THE AREA AROUND THE ROOF SCUPPERS. TWO KING STUDS WERE BURNED AND 3 TRIMMERS THAT WERE SUPPORTING A 4"X24" MICROLAM BEAM ALSO BURNED, 4FT X 10 FT OF DRYWALL WAS REMOVED, POSSIBLE HEAT DAMAGE TO A 1 1/4 COPPER WATER LINE AND POSSIBLE DAMAGE TO DATA OR COAX LINES IN THE AREA.