Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/10/2014 | INSP - FOLLOW UP CODE ENFORCE | Approved | THE BUSINESS DID CLOSE BUT THE PERMIT T13CM05899 IS FINAL FOR SERVICE UPGRADE 300 AMP PER CASE- T12DV03567 CLOSE CASE | |
| 10/14/2013 | INSP - FOLLOW UP CODE ENFORCE | Approved | T13CM05899 SERVICE UPGRADE 300 AMP - PERMIT EXPIRES ON 03/31/2014 |
|
| 09/03/2013 | INSP - FOLLOW UP CODE ENFORCE | Approved | EXTENSION GRANTED DUE TO PE WAS HIRED SEE COND NOTES | |
| 07/17/2013 | INSP - FOLLOW UP CODE ENFORCE | Approved | A NEW INSPECTION WAS CONDUCTED DUE TO NEW COMPLAINT, ONSITE INSPECTION RESULTS 1. WORKING CLEARANCE FOR MAIN DISCONNECT NOT TO CODE, THERE IS EQUIPMENT BLOCKING ACCESS. 2. IDENTIFICATION REQUIRED; NO LABELING FOR SERVICE EQUIPMENT AND THE INTERIOR PANELS TO INCLUDE ALL CIRCUITS. 3. NEW CONDUIT INSTALL REAR OF BUILDING UNDER MAIN SERVICE EQUIPMENT WITH INTERIOR FITTINGS. UNKNOWN LOCATION? 4. FILL USED OPENINGS IN THE SUB PANEL AND INTERIOR JUNCTION BOXES. 5. EXPOSED BLACK WIRE FROM INTERIOR JUNCTION BOX TO THE REACH IN COOLER. 6. INTERIOR PANEL A HAS GREEN GROUND WIRE CONNECTED TO A NEUTRAL WHITE WIRE. 7. WRONG TYPE OF BREAKER INSTALLED AT MAIN DISCONNECT, REQUIRES A T TYPE BREAKER. 8. OUTDOOR LIGHTING HAS CONDUIT WITH INTERIOR FITTINGS 9. RECEPTACLE BOX IN THE EXTERIOR HAS JUMPER WIRE FROM ADJACENT BOX. 10. MISSING COVER PLATES TO EXTERIOR RECEPTACLE BOXES 11. INTERIOR CONDUIT IS LOOSE 12. NEW A/C DISCONNECT, NO PERMITS 13. NEW ELECTRICAL WATER INSTALLED NO PERMIT NEW NOTICE OF VIOLATION WILL BE ISSUED. OWNER HAS CONTACTED NEW CONTRACTOR SABINO ELECTRIC, WILL SCHEDULE MEETING WITH CONTRACTOR NEXT WEEK. |
|
| 07/02/2013 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT WAS RENEWED EXPIRES 2-14-2014 | |
| 06/17/2013 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT IS EXPIRED | |
| 11/30/2012 | INSP - FOLLOW UP CODE ENFORCE | Approved | Permit renewed T12CM02860, schedule follow up inspection for 05-26-2013 | |
| 11/26/2012 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT T12CM02860 HAS EXPIRED SPOKE TO OWNER THIS MORNING AND ASK HIM TO REACTIVE THE PERMIT AND CALL FOR INSPECTION. | |
| 06/04/2012 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT T12CM02860 IN ISSUED STATUS FOR One circuit for freezer (220 volt), one circuit for reach in cooler. PERMIT EXPIRES ON 11/17/2012, SCHEDULE A FOLLOW INSPECTION FOR 11-17 2012 |