Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/20/2012 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE: UNITS: 4,5, MAIN HOUSE, R.V. OCCUPY THIS PARCELL. PROPERTY ZONED R-2. 106-02-200A NORTH PARCEL UNIT #4: UNIT LACKS REQUIRED PERMANENT SOURCE OF HEAT. ROOF SHOWS DETERIORATION. LEAKS INTO LIVING SPACE. LIVING ROOM CEILING DRYWALL SHOWS CRACKS, CHIPPING, FLAKING, SEPERATING. ELECTRIC SYSTEMS SHOWS OPEN GROUND UNDER TEST THROUGHOUT. LIVING ROOM CEILING FAN NOT INSTALLED PROPERLY (BOX) OPEN EXPOSED ELECTRICAL WIRING. BATHROOM LACKS REQUIRED VENTILATION. FRONT DOOR LACKS REQUIRED WEATHER PROTECTION. ATTIC OPENING NOT PROPERLY SEALED, PIGIONS. WASHER INSTALLED ON EXTERIOR: HAZARDOUS ELECTRICAL CONNECTIONS, SPLICES TAPED, EXTENSION CORDS, HOLE DRILLED THROUGH STRUCTURE WALL TO RUN EXTENSION CORD. DRAINS OUT ON TO GROUND. EXTERIOR WALLS: STUCCO, PLASTER REMOVED LEAVING OPENINGS AND HOLES FOR REPLACEMENT OF WATER LINES, GAS LINES. (NO PERMITS). UNIT #5: HAZARDOUSLY RUNNING EXTENSION CORD TO SUPPLY ELECTRIC SERVICE TO R.V. PARKED ON SAME PARCEL. ELECTRIC SYSTEM SHOWS OPEN GROUND UNDER TEST. G.F.C.I. KITCHEN DOES NOT OPERATE AS INTENDED. UNITS LACKS REQUIRED SOURCE OF PERMANENT HEAT. A/C UNIT THROUGH WALL. (DOES NOT OPERATE) NOT PROPERLY SEALED TO PROTECT THE OCCUPANT FROM EXTERIOR ELEMENTS. BATHROOM DRYWALL DETERIORATED FROM WATER LEAKS, UNDER SINK. NEW WATER LINE ADDED IN FRONT OF WASTE PIPES. HOT WATER TANK LACKS REQUIRED P.R.V. DRAIN LINE. LACKS REQUIRED ENCLOSER. WATER LINES, GAS LINES ADDED. EXTERIOR. ROOF, ROOF RAFTERS SHOW DETERIORATION DUE TO EXTERIOR WEATHER. RECEATIONAL VEHICLE: R.V. R.V. PARKED ON AND BEING LIVED IN R-2 ZONED PROPERTY.. ELECTRICAL SERVICE BEING SUPPLIED BY UNIT # 5 EXTENSION CORD. NON-PERMITED. SEWER LINE NON-PERMITTED, NOT CONNECTED PROPERLY. REFUSE/TRASH/DEBRIS SCATTERED ABOUT LOT. 2ND R.V. PLACED ON LOT, NO AXLES, NO WHEELS, STATES NO ONE LIVES IN THIS R.V. DOOR LOCKED NO KEYS. ADDED ELECTRICAL PEDESTAL, NON-PERMITTED. CONNECTION NOT WEATHER PROOF, 4 GANG CONVENIENCE OUTLET BOX ADDED NOT WEATHER PROOF. CONDEMED R.V., OWNER ON SITE, STATES HE CAN BE THERE. EXPLAINED THE CONDEMNATION, STATED WILL FIND SOME WHERE ELSE TO GO. CONDEMED R.V. LACK OF ELECTRICAL SERVICE, HAZARDOUSLY UTILIZING EXTENSION CORD TO SUPPLY POWER FROM UNIT # 5. IN LIEU OF PERMANENT SERVICE. MAIN HOUSE: VACANT @ THIS TIME. NO INSPECTION. NOTICE OF VIOLATION TO BE ISSUED. |