Permit: T12CM08036

Parcel: 106062490


Addresses:

1064 W KING ST

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/20/2012 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSTALL A SMOKE DETECTOR IN EACH BEDROOM & ONE OUTSIDE OF THE BEDROOMS. DETECTORS SHOULD BE A MINIMUM 3' FROM AIR VENTS AND NO MORE THAN 12"BELOW THE CEILING. INSTALL GLOBES OVER THE LIGHT BULBS IN THE CLOTHES CLOSETS. COVER PLATES MISSING AT LB UNDER PANEL & AT J BOX NEXT TO PANEL. FILL IN OPEN KNOCKOUTS IN J BOX & DISCONNECT RE ATTACH CONDUIT INTO J BOX. OUTDOOR RECEPTACLES UNDER PANEL TO BE GFI OR REMOVE